TK-100 Dew point  On-line / Transmitter

TK-100 Dew point  On-line / Transmitter

Description

You can easily start measurement. TK-100 On-line Hygrometer offers you a complete set for continuous measurement, including display monitor. What you need is 100 to 240 VAC power supply and sample gas connection. Also, you can select TK-100 Dew Point Transmitter, which can be used “stand-alone” basis with 4-20 mA signal output, powered by 12-28 VDC.

Features
Fully calibrated at TEKHNE factory
Innovative Al₂O₃ technology
Measuring range:-100 to +20 ℃ dp
Measuring range:-100 to +20 ℃ dp

 

  • Fully calibrated at TEKHNE factory
  • Innovative Al2O3 technology
  • Measuring range:-100 to +20 ̊C dp
                                        0-2000PPM (optional)
  • Accuracy:± 2 ̊C dp
  • Pressure:104 Pa to 30 MPa
  • TK-100 On-line with monitor
          TK-100 Transmitter without monitor
  • Easy installation

 

 

 

Easy

TEKENE Corporation, a Japanese manufacturer, experienced dew point measurement over 40 years, is manufacturing innovative TK-100 series Hygrometer.

You can easily start measurement. TK-100 On-line Hygrometer offers you a complete set for continuous measurement, including display monitor. What you need is 100 to 240 VAC power supply and sample gas connection. Also, you can select TK-100 Dew Point Transmitter, which can be used “stand-alone” basis with 4-20 mA signal output, powered by 12-28 VDC.

 

High Quality

TEKENE Ceramic Sensor by Al2O3 is designed to secure the best mixture of accuracy, high response speed, and long-term stability. Most advanced sensor technology is used for this purpose.

Also, the advanced microprocessor technology realized fully temperature compensation mechanism, which minimizes the effect by process temperature to the dew point measurement. The -100 to +20℃dp output is converted to stable and linear 4-20 mA output in the TK-100 Transmitter.

 

Flexible

TEKHNE TK-100 series are for dew point measurement in air or inert gas. Put the sensor into your process line through 5/8” UNF or 1/8” NPT by using Optional sampling block. 1/8 DIN display unit can be set up to 1,000 m far away from the Transmitter.

The flow rate for the process line should be 1 to 10 NL/min (with optional sampling block) or 0.5 to 10 m/sec (without optional sampling block), at a temperature between -20 to +60℃ and in-line pressure up to 30MPa.  Filters for removing dust are always recommended.

 

Monitor for TK-100 On-line

If power supply and display are required, TK-100 On-line monitor is included in TK-100 On-line.

 

Technical Specifications

TK-100 Transmitter

Measurement range          -100 to +20 °C dp

                                         0-2000 PPM (optional)

Accuracy                            ±2 °C dp

Analog output                   4-20 mA (3-wire technology)

Power supply                    12 to 28 VDC

Operating temperature    -20 to +60 °C

Operating pressure           104 Pa to 30 MPa

TK-100 Monitor

Display                              5 digit LED

Measurement Ranges      -100 to +20 °C dp

Outputs                             liner 4-20 mA

Alarm Relays                     3 relay contact

Operating environment    0 to +50 °C (35 to 85 %RH)

Power supply                    100 - 240 VAC, 50/60 Hz

Panel Cutout                     92 W x 45mm H